Save
A pilot study comparing the MSFC score to the DAM application, a self-assessment solution for MS patients
Author(s): ,
S Medjebar
Affiliations:
Ad Scientiam
,
C Louapre
Affiliations:
Department of Neurology, Pitié Salpêtrière Hospital, APHP;CIC_1WP, IHU-A-ICM, Paris, France, ICM - Institut du Cerveau et de la Moelle épinière
,
R Debs
Affiliations:
Department of Neurology, Pitié Salpêtrière Hospital, APHP
,
C Peczynski
Affiliations:
Ad Scientiam
E Maillart
Affiliations:
Department of Neurology, Pitié Salpêtrière Hospital, APHP;WP, IHU-A-ICM, Paris, France
ECTRIMS Online Library. Medjebar S. Sep 15, 2016; 146196
Samir Medjebar
Samir Medjebar
Login now to access Regular content available to all registered users.

You may also access this content "anytime, anywhere" with the Free MULTILEARNING App for iOS and Android
Abstract
Discussion Forum (0)
Rate & Comment (0)

Abstract: P356

Type: Poster

Abstract Category: Clinical aspects of MS - Clinical assessment tools

Background: Multiple Sclerosis Functional Composite score (MSFC) is one of the gold standard for multiple sclerosis (MS) patient clinical evaluation. However, its practical implementation is not always optimal as it can prove to be very time consuming. Moreover, it often constrains the range of tests used and is not a particularly good marker for patient real life disability status.

A mobile application called Digital Self-Assessment for Multiple Sclerosis (DAM) was developed in order to replicate each of MSFC tests available in order to assess MS progression in the patient environment.

Objective: To establish a correlation between application DAM and MSFC.

Methodology: DAM was created using the Apple open source Research Kit. An ongoing pilot study is currently recruiting 30 patients with an established diagnosis of MS. Patients are selected during a consultation at the Neurology department of the Pitié-Salpêtrière Hospital (France). Each patient is given access to DAM on their own or a provided iPhone. During the enrolment visit, patients have to complete a MSFC and DAM evaluation (V0). Through a push-notification on their phone, patients are reminded to perform two DAM evaluations at home at days 30 (V1) and 60 (V2). At day 90 (V3), they have to come back to hospital for a second MSFC and DAM evaluation.

Interim analyses were performed in April 2016 using correlation tests after 24 V0 and 12 V1 were completed. A comparison between each test of DAM and MSFC was done in order to evaluate the reproducibility and robustness of DAM tests.

Results: Reproducibility of MSFC on smartphone seems to be excellent (correlation between MSFC V0 and DAM V0 Z-scores, r=0.79, p< 10-5). Timed 25-Foot Walk (T25-FW, r=0.68, p< 10-3) and Paced Auditory Serial Addition Test (PASAT, r=0.65, p< 10-3) have the best reproducibility. Robustness of DAM seems to be good (correlation between DAM V0 and V1 at day 30, r= 0.68, p< 0.05), particularly for the 9HPT (r=0.77, p< 10-2) and PASAT (r=0.67, p< 0.05).

Conclusions: These results reinforce the idea that a smartphone application would be a good self-assessment tool for patients with MS. A new version of the application taking into accounts these interim results is under development. Qualitative insights from patients and clinicians will also be used to enhance usability and clinical relevance with updated or new tests. Further validation will also be required using a larger sample size to improve the confidence level.

Disclosure:

S Medjebar: affiliate of Ad Scientiam

C Louapre: travel grant from Genzyme and Novartis

R Debs: nothing to disclose

C Peczynski: affiliate of Ad Scientiam

E Maillart: conference fees from Teva, Biogen, Genzyme, Merck and Novartis / travel Grant from Teva, Biogen, Novartis and Genzyme

Ad Scientiam: privately held research company which received a research grant from Roche France for the conduct of this study

Code of conduct/disclaimer available in General Terms & Conditions
Anonymous User Privacy Preferences

Strictly Necessary Cookies (Always Active)

MULTILEARNING platforms and tools hereinafter referred as “MLG SOFTWARE” are provided to you as pure educational platforms/services requiring cookies to operate. In the case of the MLG SOFTWARE, cookies are essential for the Platform to function properly for the provision of education. If these cookies are disabled, a large subset of the functionality provided by the Platform will either be unavailable or cease to work as expected. The MLG SOFTWARE do not capture non-essential activities such as menu items and listings you click on or pages viewed.


Performance Cookies

Performance cookies are used to analyse how visitors use a website in order to provide a better user experience.



Google Analytics is used for user behavior tracking/reporting. Google Analytics works in parallel and independently from MLG’s features. Google Analytics relies on cookies and these cookies can be used by Google to track users across different platforms/services.


Save Settings